Loading...
HomeMy WebLinkAbout503 03-23-1976ORDINANCE NO. 503 AN ORDINANCE AMENDING ORDINANCE NO. 147 IDENTIFIED AS "THE SUBDIVISION RULES AND REGULATIONS ". PRO- VIDING FOR AN AMENDMENT TO SECTION 47 "WATER AND SEWER REQUIREMENTS" PARAGRAPH (a) WATER, PARAGRAPH (b) SEWER, AND MATERIAL REQUIREMENTS FOR WATER AND SEWER. WHEREAS, the City of Euless finds it in the best interest of the p,iblic to allow new materials for water and sewer mains; NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF EULESS, TEXAS: read: That Ordinance #147, Section 47 Paragraph (a) Water be changed to read: (a) Water The developer shall install a complete water system to serve his subdivision. The size of lines to be installed shall be determined by the City master water plan and the type of development to be served. Feeder mains shall not be smaller than eight (8) inches and if possible the system shall be looped. Valves shall be in- stalled as required for control of the system. Fire hydrants shall be installed on five hundred (500) feet radius in R -1 and R -2 zoning and on three hundred fifty (350) feet radius in all other zones. Cast iron or steel cylinder concrete pipe may be placed on the native earth bottom if suitably graded and uniformly supported, but in all asbestos cement pipe installations, the trench shall be undercut and a minimum of four (4) inches of cushion sand bedding placed under the pipe. Fire hydrants, valves and pipe ends shall be blocked. Developers shall install all water taps including meter boxes to grade. Water lines shall be cast iron or asbestos cement pipe and no less than class one hundred fifty (150) water pipe or P.V.C. Johns - Manville Ring - Tite or approved equal and complying with AWWA Standard C- 900 -75. That Ordinance #147, Section 47, Paragraph (b) Sewer be changed to (b) Sewer The developer shall install a complete sewerage system to serve his subdivision. The size shall be determined by the City master sewer 'plan and the type of development to be served. Sewer lines` shall be vitrified clay or P.V.C. Johns - Manville or approved equal and conforming to ASTM Specifications D3034, SDR35 and shall be installed a minimum of four and one -half (42) feet below the lowest finished grade to be served. The pipe shall be placed on the natural undisturbed earth foundation, which has been carefully shaped to fit the lower part of the pipe extensions for at least fifteen (15) per cent of its' overall height. Bell holes or recesses for bells of the pipe shall be excavated for every joint, and shall be of sufficient size and depth to relieve the bell of all load, permitting the barrel of the pipe to be firmly embedded throughout its' entire length, and to provide ample space for making the joint. P.V.C. joints shall be rubber locked ring type. Since there has'been created and exists an urgency and an emergency for the immediate preservation of the public peace, health and welfare requiring that this ordinance be adopted as an emergency measure by the favorable vote of four or more of the Euless City Councilmen, this ordinance is passed as an emergency measure, and shall take and have effect and be in full force from and after its passage. PASSED AND APPROVED by the City Council of the City of Euless, Texas, on the 23rd day of March , 1976. APPROVED: Mayor ATTEST: City Secretary APPROVED AS TO FORM: City Attorney